Imaging components. Procurement support.
MINI 640-2 Radiometric Thermal imaging module

Supplier product photo: the module with its 9.1 mm lens (left) and the 21 × 21 mm core (right).

Thermal imaging module

MINI 640-2 Radiometric

A 640 × 512 uncooled VOx module with calibrated temperature measurement in two ranges from −20°C to 650°C, typical accuracy of ±2°C or ±2%, and image, temperature data and control over USB Type-C.

No minimum order · In stock · Samples ship within 2–3 working days of payment

640 × 512Resolution
−20°C to 650°CMeasurement range
±2°C or ±2%Typical accuracy
USB Type-CImage + temperature data

Product overview

Thermal image and temperature data on one cable.

Two measurement ranges

−20°C to 150°C in high-quality mode and 100°C to 650°C in wide-range mode, with typical accuracy of ±2°C or ±2%.

One USB Type-C cable

Thermal image, temperature data and control run over one USB Type-C connection. On a Windows PC the picture appears as a USB camera, with no driver to install. Temperature display and readout are done through TSDK, our SDK for this module, with builds for Linux (Ubuntu, Raspberry Pi and Jetson); it has been tested on our modules, comes at no extra charge and is provided after payment.

Shutter and shutterless correction

Both shutter correction and shutterless algorithm correction are listed for non-uniformity correction.

Technical reference

Specifications

Specifications are supplier document values measured under laboratory conditions.

Request a quote
MINI 640-2 Radiometric · Listed configuration
ParameterValue
Detector & image
DetectorVOx uncooled infrared FPA
Resolution640 × 512 pixels
Pixel pitch12 μm
Spectral band8–14 μm
Detector frame rate30 Hz
NETD≤ 40 mK at 25°C, F/1.0, 25 Hz
Thermal time constant< 12 ms
Non-uniformity correctionShutter correction / shutterless algorithm
Polarity / palettesWhite hot, black hot and pseudo-colour palettes
Digital zoom1.0–8.0× continuous, 0.1 steps
Temperature measurement
Measurement ranges−20°C to 150°C (high-quality mode); 100°C to 650°C (wide-range mode)
Accuracy±2°C or ±2% (typical)
Ambient temperature for measurement−10°C to +70°C
Lens
Fitted lens9.1 mm F1.1, fixed focus
Field of view48.7° × 38.6°
IFOV1.3 mrad
Lens weight10.5 g ±5%
Other listed lenses13.5 mm F1.0 (31.9° × 25.7°); 18 mm F1.1 (24.2° × 19.5°)
Interfaces & power
Interface versionsUSB Type-C, MIPI (2-lane) or DVP, all with temperature data
Module interfacesDVP / USB 2.0 / MIPI digital video
CommunicationUART / I²C / USB 2.0
Power supply5 V
Typical power consumption< 0.7 W, USB output at 25°C
Mechanical & environment
Core dimensions21 × 21 × 10.3 mm, excluding lens
Core weight< 8.6 g, excluding lens
Operating temperature−40°C to +80°C (imaging); −10°C to +70°C (measurement)
Storage temperature−50°C to +85°C
Humidity5%–95%, non-condensing
Vibration6.06 g random, all axes
Shock80 g, 4 ms, saw-tooth, 3 axes, 6 directions

Interface definition

Connector pinout

The core uses a 50-pin Hirose DF40 board-to-board connector (DF40C-50DP-0.4V). The USB version ships with a USB Type-C board.

For selection only. If you need hardware development documents, tell us.

MINI 640-2 Radiometric · 50-pin connector
PinsSignalFunction
1, 50VDD5.0Power input; the module runs from a single 5 V supply
3, 48VDD3.3Reserved; no supply needed
2, 4, 7, 10, 21, 25, 26, 30, 41, 44, 47, 49DGNDGround
14, 15USB_DP, USB_DMUSB 2.0 data
8, 9—Not used on this model
12, 13, 40, 39, 38, 37MIPI_CK_P/N, MIPI_D0_P/N, MIPI_D1_P/N2-lane MIPI output
20, 33, 19, 32, 11, 18, 34, 17, 35, 16, 36DVP_CLK, DVP_VSYNC, DVP_HSYNC, DVP_DATA15–8DVP video output; DATA15 is the MSB, 1.8 V by default (3.3 V by command)
43, 42UART0_TX, UART0_RXControl UART, 3.3 V
24, 27UART1_TX, UART1_RXDebug UART or general I/O, 3.3 V
22, 29I2C_SLV_SCK, I2C_SLV_SDAI²C slave, 1.8 V by default (3.3 V by command)
6, 45IIC_MST1_SCK, IIC_MST1_SDAI²C master, 3.3 V
23DVP_FSYNCExternal sync input, or general I/O
28WORK_MODEPull high for update mode; leave unconnected otherwise
31NrstPull low to reset; leave unconnected otherwise
5, 46NCNot for use

ENGINEERING & PROCUREMENT

Questions before design-in

How is MINI 640-2 Radiometric different from MINI 640-2?

MINI 640-2 is an observation module: a 60 Hz detector, CVBS and USB 2.0 video, and no calibrated temperature output. MINI 640-2 Radiometric adds calibrated temperature measurement: two measurement ranges, typical accuracy of ±2°C or ±2%, and temperature data over USB Type-C. Both use a 640 × 512, 12 μm VOx detector in the 21 × 21 mm format.

What is the difference between a radiometric and a non-radiometric thermal camera module?

A non-radiometric module shows relative heat differences as an image. A radiometric module is calibrated to output temperature values, so you can read the temperature of a spot or area. MINI 640-2 is non-radiometric; MINI 640-2 Radiometric outputs temperature data over USB with typical accuracy of ±2°C or ±2%.

What temperatures can MINI 640-2 Radiometric measure?

The manual lists −20°C to 150°C in high-quality mode and 100°C to 650°C in wide-range mode, with typical accuracy of ±2°C or ±2%. Temperature measurement is specified at an ambient temperature of −10°C to +70°C; imaging works from −40°C to +80°C.

Does temperature data come over USB?

Yes. Thermal image, temperature data and control run over one USB Type-C cable. Plug the module into a Windows PC and you see the thermal picture: Windows sees it as a USB camera, with no driver to install; on a laptop with a built-in webcam, disable the built-in camera first. Temperature display and readout are done through TSDK, our SDK for this module, with versions for Linux (Ubuntu, Raspberry Pi, Jetson). TSDK has been tested on our modules and comes at no extra charge. If you need it, tell us: we provide it after payment is confirmed, before the module ships. Tell us your host platform when you request a quotation.

What temperature data does MINI 640-2 Radiometric output?

Full-frame temperature data or spot readings (maximum, minimum and center), depending on your application. Tell us which you need when you request a quotation.

Which lenses are available for MINI 640-2 Radiometric?

The in-stock sample uses a 9.1 mm F1.1 lens (48.7° × 38.6°). The supplier manual also lists 13.5 mm F1.0 (31.9° × 25.7°) and 18 mm F1.1 (24.2° × 19.5°) lenses for the 640 × 512 version. Both are non-standard lenses: samples ship within 15 working days of payment, and prices are confirmed in your quotation.

Is MINI 640-2 Radiometric also available in 384 × 288 and 256 × 192?

Yes. The same radiometric core comes in 384 × 288 (30 Hz) and 256 × 192 (25 Hz) versions with the same 21 × 21 mm format, measurement ranges, typical accuracy and interfaces. Both are supplied with a 4 mm F1.1 lens: 64.1° × 48.8° on the 384 version and 45.5° × 33.5° on the 256 version. Samples are in stock and ship within 2–3 working days of payment.

What comes with a MINI 640-2 Radiometric sample?

The module with its 9.1 mm F1.1 lens, the USB Type-C board and a USB 2.0 cable. If you need TSDK, it is provided separately after payment is confirmed, at no extra charge. If you plan to design your own host board, tell us which documents you need.

Which connector does the core use?

The core uses a 50-pin Hirose DF40 board-to-board connector (DF40C-50DP-0.4V), with a single 5 V supply. The pin table on this page is for selection only; if you need hardware development documents, tell us.

Is there a minimum order, and how fast do samples ship?

There is no minimum order; you can start with one unit. MINI 640-2 Radiometric is in stock, and samples ship within 2–3 working days of payment. Prices are quoted for your configuration, quantity and destination.

Prepare the next step

Order a sample

Tell us the application, lens, output and quantity. We confirm the sample configuration and price before you order.

DESIGN-IN GUIDES

Integrate a thermal core.

01
Design-in guide

How wide, how far: choosing a lens for a 640 × 512 thermal core

Choose a lens for a 640 × 512 thermal core: coverage width, pixel size and distance for 9.1, 13.5 and 18 mm lenses, and horizontal vs diagonal FOV.

02
Design-in guide

USB, MIPI or DVP: getting temperature data out of a radiometric thermal core

How temperature data leaves a radiometric thermal core over USB, MIPI CSI-2 or DVP, why analog video cannot carry it, and five questions before design-in.

03
Design-in guide

Designing a 21 × 21 mm thermal core into your housing: mounting, connector, power and the window

Mechanical checklist for a 21 × 21 mm thermal core: size with lens, M2 mounting, 50-pin DF40 connector, 5 V power, infrared window, heat and ambient limits.

04
Design-in guide

“±2°C or ±2%”: what a radiometric module’s accuracy figure means on a real target

What “±2°C or ±2%” accuracy covers, and what matters more on a real target: emissivity, reflections, spot size, distance, windows, ambient temperature, NUC.

05
Design-in guide

Thermal cores on drones, vehicles and trains: when the image smears and when the temperature reads low

Why a thermal core smears on drones, vehicles and trains, why a higher frame rate does not fix it, and at what speed temperature readings drop (calculated).

06
Design-in guide

Putting a thermal core behind a window: why glass fails, what germanium needs, and how the window changes your readings

Why glass and most plastics block long-wave infrared, what a germanium window and its coatings need, how a window shifts readings, and how to size it.

07
Design-in guide

Thermal cores on patrol and inspection robots: typical specs, and what to check before you choose one

What thermal payloads on inspection robots use, and what to check: pixels on target, field of view in aisles, temperature range, stop-and-measure, close focus.

08
Design-in guide

Choosing a 640 × 512 radiometric thermal module with USB-C: 8 things to check before you order a sample

8 checks before ordering a 640 × 512 radiometric thermal module sample: ranges, USB-C, first plug-in, temperature data, host software, lens, shutter, contents.

09
Design-in guide

Thermal core or complete thermal camera: what a 21 × 21 mm core does on its own, and what your product has to add

What a 21 × 21 mm radiometric thermal core does on its own, what your product adds (housing, window, recording, network, alarms), and when to buy a camera.

10
Design-in guide

Raspberry Pi, Jetson or a microcontroller? Choosing the host computer for a USB radiometric thermal module

Choosing the host for a USB 640 × 512 radiometric thermal module: data rates, USB 2.0 limits, why a microcontroller is not enough, power and storage per hour.

11
Design-in guide

256, 384 or 640? Choosing thermal resolution by field of view and pixels on target

How to choose 256 × 192, 384 × 288 or 640 × 512: the lens sets the detail per pixel, the resolution sets the width. Lens table, worked example, power and size.

12
Design-in guide

Adding a visible camera next to a thermal core: field of view, parallax and alignment

Pairing a visible camera with a 640 × 512 thermal core: two windows, matching 5:4 to 4:3 or 16:9, parallax that changes with distance, alignment, timing.

13
Design-in guide

Radiometric or not? Choosing between a temperature-measuring thermal core and an imaging core

Radiometric or imaging 640 × 512 thermal core? One question decides it, plus how the two differ in frame rate, outputs, lens focus and ambient range.

14
Design-in guide

Finding people from a drone at night: resolution, lens and altitude for a thermal core

Finding people from a drone at night with a 640 × 512 thermal core: pixels on target at 30–120 m, ground footprint, lens focus, motion smear and conditions.

15
Design-in guide

Close-range electrical inspection with a wide-angle radiometric thermal core: field of view, focus and emissivity

Close-range electrical inspection with a wide-angle 640 × 512 radiometric core: coverage at 0.5–1 m, pixel size, fixed-focus near limit, emissivity and load.

16
Design-in guide

Planning a robot’s thermal inspection route: viewpoints, stops and readings you can compare

Planning an onboard thermal inspection route for a robot: viewpoint distance and angle, settling after a stop, repeatable pose, emissivity, alarms and data per stop.

17
Design-in guide

Reading a thermal camera core datasheet: what each number means and the conditions behind it

How to read a thermal camera core datasheet: NETD and its f-number, accuracy wording, ambient ranges, power and weight conditions, field of view and detection distances.

Product documents

Information for your evaluation.

Start with the product overview. Ask us for the technical documents available for your selected configuration.

MINI 640-2 Radiometric

Thermal imaging module · Parameter sheet · On request

Request documents

Purchasing support

From evaluation to ordering.

01

Configuration coordination

We clarify your product and application requirements, then coordinate supplier confirmation of the proposed configuration.

02

Sample confirmation

We record the agreed sample model, configuration and included items, then review any changes before an order proceeds.

03

Order follow-up

We track supplier progress, coordinate order documents and follow up on open issues, keeping the next step and responsible party clear.

Continue exploring

Related component

All products